Cupping Care & Cleaning Guide

This guide applies exclusively to ICUPPING-branded products and should not be interpreted as cleaning, disinfection, or sterilization guidance for products manufactured or sold by other brands.

Keep your cupping tools clean, safe, and ready for your next session.

Proper cleaning helps maintain your ICUPPING products and supports hygienic use. Follow the instructions for your specific cupping system.

 Cleaning Method Classic Silicone Basic PC CUVIA Hybrid
Mild soap & warm water ✅ ✅ ✅
Boiling water ✅ ❌ ❌
Dishwasher ✅ ❌ ❌
Ultrasonic cleaning ⚠️ Not validated ⚠️ Not validated ⚠️ Not validated
High-temperature sterilization ✅ ⚠️ Not validated ⚠️ Not validated

 

1. Everyday Cleaning — Home Use

For routine home use on healthy, intact skin, we recommend three simple steps.

Step 1 — Wash

Use warm water and a small amount of mild liquid dish soap. Gently clean the inside and outside of each cup with your hands or a soft, non-abrasive cloth.

Step 2 — Rinse

Rinse thoroughly with clean water to remove all soap and massage oil residue.

Step 3 — Dry

Allow the cups to air-dry completely in a clean area before storing them.

Recommended Household Cleaners

Choose a:

  • Mild, preferably pH-neutral liquid dish soap
  • Fragrance-free or dye-free formula, when available
  • Non-abrasive cleaner suitable for repeated washing

Avoid: abrasive pads, strong solvents, aggressive alkaline cleaners, and other chemicals that may damage the material.

Can I Boil My Silicone Cups?

Yes! ICUPPING Classic silicone cups can be cleaned using boiling water.

Our silicone material has a specified maximum heat resistance of 220°C (428°F).

For boiling-water care:

  • Use only the all-silicone Classic cups.
  • Keep the cups submerged in water and away from direct contact with the heated base of the pot.
  • Let the cups cool before handling.

Please note: The 220°C rating describes the silicone material's heat resistance. It does not mean that boiling has been validated as a medical sterilization process.

Do not boil Basic PC cups, assembled CUVIA cups, hand pumps, valves, or connecting tubes.

2. Professional Care — Clinics & Therapists

Professional cupping requires more than routine household cleaning.

Dry Cupping — Intact Skin

For cups used on intact skin:

  1. Clean the cups thoroughly after every patient.
  2. Rinse away detergent and visible residue.
  3. Follow an appropriate, validated disinfection procedure before reuse.
  4. Store clean and disinfected cups in a protected, dry area.

The Clean Needle Technique Manual recommends at least intermediate-level disinfection for cupping equipment used on intact skin.

Professional Cleaning Products

Healthcare facilities commonly use neutral-pH or enzymatic instrument detergents.

Examples include:

  • STERIS Prolystica HP Neutral Manual Cleaner
  • STERIS Prolystica HP Enzymatic Manual Cleaner

These products are examples of professional cleaning detergents, not disinfectants.

For disinfection, facilities should select an appropriate EPA-registered healthcare disinfectant with the required claims, following its label and the relevant infection-control standards.

Compatibility notice: ICUPPING has not validated these named detergents or a specific chemical disinfection cycle for every ICUPPING product and component. Check chemical compatibility before use.

Wet Cupping — Blood Exposure or Broken Skin

Higher infection-control standards apply whenever cupping involves blood or non-intact skin.

Unlike ordinary dry cupping, equipment exposed to blood may require reprocessing as a semicritical medical device.

This generally involves:

  • Thorough cleaning to remove blood and organic material
  • A validated high-level disinfection or sterilization process, as appropriate
  • Proper handling and protected storage
  • Compliance with applicable clinical infection-control requirements

Examples of high-level disinfectants used in healthcare include CIDEX OPA and STERIS Resert XL HLD.

However, these products have not been validated for compatibility or effective reprocessing of ICUPPING cups.

Important safety notice: ICUPPING does not currently provide a validated reprocessing protocol for reusing Classic, Basic, or CUVIA products after blood exposure. Do not assume that washing, boiling, ultrasonic cleaning, or soaking in disinfectant makes these products safe for reuse following wet cupping.

Where an appropriate validated reprocessing method is unavailable, use purpose-designed, single-use equipment for wet cupping.

3. Frequently Asked Questions

Can I use an ultrasonic cleaner?

Ultrasonic cleaning can help remove residue from some medical instruments, but it does not replace disinfection or sterilization. Ultrasonic cleaning has not yet been validated for ICUPPING products.

Can I put my cups in the dishwasher?

We recommend handwashing. Dishwasher cycles and detergents vary and have not been validated for most of our products.

Can I use alcohol or bleach?

Avoid routine use of concentrated alcohol, bleach, and aggressive chemical cleaners unless the exact formulation, concentration, and method have been confirmed compatible with the product.

How often should I clean my cups?

  • Home use: After every session.
  • Professional use: After every patient, followed by the required disinfection process.
  • Blood exposure: Do not reuse without a validated clinical reprocessing procedure.

How should I store my cups?

Store completely dry cups in a clean, protected container, away from direct sunlight, excessive heat, and contamination. Keep used equipment separate from clean equipment.

Need More Help?

Different cupping methods and clinical environments may require different cleaning procedures.

If you have questions about your ICUPPING products, please contact us at support@icupping.com.

This guide provides general product-care information. It does not replace professional infection-control standards, disinfectant manufacturer instructions, or validated medical-device reprocessing procedures.